CTI Products RadioPro Betriebsanweisung Seite 44

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 56
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 43
RadioPro Dispatch Installation and Configuration Guide
44
c. If stand-alone I/O points are needed
using IP-based Advantech modules,
click the
New Advantech Button. A
window similar to the one at right will
be displayed. Before an Advantech
module is accessed by RadioPro
Dispatch, it should have been
configured using Adam/Apax .NET
Utility. See Appendix for details.
Enter the
IP Address, Module Type, and Poll Frequency for this Adam module. The Auto Detect
button can be used to automatically determine the Module Type. The number of Digital Outputs and
Inputs will be listed near the bottom of this window
The
Test Module button may be used to toggle the state of Output 0. The Ping button may be used to
send a Ping command to the module to determine if it is accessible from this RadioPro Dispatch
console PC.
d. If radio-based I/O points are needed
using Tallysman Sprite TW200
modules, click the
New SpriteBox
Button. A window similar to the one at
right will be displayed. Before a Sprite
TW200 module is accessed by
RadioPro Dispatch, it should have been
configured using Sprite Configurator.
See Appendix for details.
Choose a
Gateway and a Radio ID for the radio I/O to be accessed.
3. Configure the I/O pins for each I/O module.
a. Click the
Pin Monitor & Control folder
under the
Telemetry folder, and then
click the Add Digital Pin Control
button.
b. In the
Pin Setup window, choose the Telemetry
Device, IO Type, and Pin # for each pin on each
I/O module configured in Step 2 above. For
Outputs, choose an
Output action. For Inputs,
complete the
State Table, choosing an
appropriate
Color and Text to display for each
state.
4. Save the I/O configuration.
a. Click the
Apply button in the lower right corner of the Dispatch Settings window.
b. From the
File menu, choose Save to save the new configuration to the existing configuration file, or
choose
Save As to save the new configuration to a new filename.